OPC UA Client Development with C#, VB.NET and C++/CLI
The OPC UA .NET Client SDK enables the development of OPC UA client applications according to OPC UA v1.03 and higher. To establish a client connection, the IP address and the transport protocol scheme are sufficient. To establish a client connection, the server address together with the transport protocol scheme (see below) is sufficient. No membership in the OPC Foundation and no licence other than that for Traeger's SDK is required for development!
An OPC UA client can be realised with a few lines of code. The OPC UA Client shown below reads the value of a data node with the NodeId "ns=2;s=Hello" and outputs it on the command line.
Access to the respective data nodes works with the usual NodeId syntax (even after optional resolution via the Browse and Translate services). Any .NET language such as C#, VB.NET and C++/CLI can be used for programming. The interfaces themselves only differ in terms of the programming language used.
OPC DA servers must (also) be addressed? The SDK is also available as OPC UA .NET Client SDK + OPC Classic with support for OPC Classic (consisting of OPC DA, OPC HDA and OPC AE)!
The data of the OPC UA Server should be retrievable via REST API, stored in a database, forwarded to other devices or simply visualised? Take a look at our OPC UA Middleware: Codabix Industrial Edge
Still undecided? We will be glad to advise you free of charge and without obligation: Contact us now!
Once purchased, a licence is valid indefinitely (= unlimited licence lifetime) and allows the development of any number of products as well as their unlimited distribution without further licence costs (= royalty-free). Included are 12 months Top Level Support by our developers as well as updates including new functions.
Shortly before the support expires, it is possible to extend it for at least another 12 months for 15% of the current list price. Updates and new functions can only be obtained with valid support. Support requests can still be submitted, but will be processed on a priority basis depending on their scope. Up to one month before the expiry of active support, we will notify you of the possibility of support renewal. Support renewal is possible at any time in the first year after expiry of support for 30%, in the second year for 60% and in the third year for 80% of the current list price. From the fourth year onwards, a new licence must be purchased for the support renewal.
A Branch License applies to all developers who use the product for software development exclusively at the location (= a postal address at which development takes place) according to the licence agreement.
A Single Developer Licence applies to a single developer who, according to the licence agreement, is the only one (= full contact details of the developer and employer) to use the product for software development.
Controllers, components and entire plants
Scalar values, arrays and structured data types
Events, alarms, conditions, methods and files
Location, namespaces, version, status and system time
High-performance communication and consistent data
Constant connections through automatic reconstruction
Identifiers in OPC UA NodeId, BrowseName and BrowsePath format, also via LINQ to Nodes
1 to 8, 16, 32 and 64 bit data length - also as array and matrix
Byte, Int16, UInt16, Int32, UInt32, Int64 and UInt64 - also as array and matrix
Float (single) and Double - also as array and matrix
TimeSpan and DateTime (UTC)
Char to string - also via byte with own encoding
dynamic or own .NET types with implicit and explicit coding
C#, VB.NET and C++/CLI
.NET Framework 4.6+, .NET Standard 2.0+, .NET Core 3.1+,
.NET 5.0+ and .NET 6.0+
Microsoft's CLR, Mono, Xamarin, UWP and Unity
Windows, Linux, macOS, Android, iOS and Docker